Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 174
Filtrar
1.
Clin Endosc ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38725401

RESUMO

Background/Aims: The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO). Methods: Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared. Results: Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7 vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS. Conclusions: No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.

2.
Surg Endosc ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649493

RESUMO

BACKGROUND AND AIMS: Endoscopic multiple plastic stents are an established first-line treatment for anastomotic biliary stricture (ABS) management after liver transplantation (LT). Fully covered self-expandable metallic stents (FCSEMSs) have recently been used with favorable outcomes, but long-term treatment outcomes remain an issue for ABS. We evaluated the long-term outcomes of FCSEMS for the management of refractory ABS after LT. METHODS: We reviewed the prospectively collected and maintained endoscopic retrograde cholangiography database at Asan Medical Center to retrieve consecutive post-LT ABS cases that underwent an endoscopic FCSEMS placement between August 2009 and August 2019 after MPS placement failure. RESULTS: A total of 34 patients were enrolled in this study. Technical success had been achieved in all subjects (100%). The median stent placement duration was 3.1 months (IQR 2.7-6.1). Stricture resolution was achieved in 26 patients (clinical success 76.5%, 95% confidence interval 62-91). Early adverse events developed in 3 patients (8.8%), including distal stent migration. Late adverse events occurred in 9 patients (26.5%), including cholangitis (n = 7, 20.6%) and asymptomatic distal stent migration (n = 2, 5.9%). The median follow-up period was 57.9 months (IQR 51.9-64.3). Stricture recurrence occurred in 3 of 26 patients who achieved clinical success (11.5%). CONCLUSIONS: FCSEMS placement appears to be an effective and advisable intervention for refractory ABS as it can provide persistent stricture improvement over the long-term.

3.
Eur Radiol Exp ; 8(1): 40, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38565836

RESUMO

BACKGROUND: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. METHODS: The study involved 42 Sprague-Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. RESULTS: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. CONCLUSIONS: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. RELEVANCE STATEMENT: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. KEY POINTS: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis.


Assuntos
Hipertermia Induzida , Nanopartículas Metálicas , Ratos , Animais , Ouro , Silicones , Estudos de Viabilidade , Ratos Sprague-Dawley , Esôfago , Stents
4.
Clin Endosc ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38454545

RESUMO

Colonic stent placement is a commonly used bridging strategy for surgery in patients with obstructive colorectal cancer. The procedure involves the placement of a self-expandable metallic stent (SEMS) across the obstructive lesion to restore intestinal patency and alleviate the symptoms of obstruction. By allowing patients to receive surgery in a planned and staged manner with time for preoperative optimization and bowel preparation, stent placement may reduce the need for emergency surgery, which is associated with higher complication rates and poorer outcomes. This review focuses on the role of colon stenting as a bridge to surgery in the management of obstructive colorectal cancer. SEMS as a bridge to surgery for left-sided colon cancer has been demonstrated to be particularly useful; however, further research is needed for its application in cases of right-sided colon cancer. Colon stent placement also has limitations and potential complications including stent migration, re-obstruction, and perforation. However, the timing of curative surgery after SEMS placement remains inconclusive. Considering the literature to date, performing surgery at an interval of approximately 2 weeks is considered appropriate. Therefore, colonic stent placement may be an effective strategy as a bridge to surgery in patients with obstructive colorectal cancer.

5.
Eur Radiol Exp ; 8(1): 24, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38369648

RESUMO

BACKGROUND: Knowledge of the characteristics of self-expanding metal stents (SEMSs) is essential during selection process to ensure the best therapeutic outcomes for patients with malignant biliary obstruction. The aim of this study was to evaluate the characteristics of four commonly used SEMSs. METHODS: This in vitro study analyzed the radial force (RF), crush resistance (CR), axial force (AF), conformability, surface quality, foreshortening, and radiopacity of the following SEMSs: uncovered Wallflex™, EGIS single bare, Zilver 635®, and E-Luminexx™. Two samples of each SEMS type were included in this study, all having identical specifications with a diameter of 10 mm and a length of 6 cm. One sample from each type was analyzed for surface quality, followed by CR, conformability, and foreshortening. The other sample was analyzed for radiopacity, followed by RF and AF. RESULTS: The uncovered Wallflex™ exhibited low RF, high CR, high AF, good conformability, poor surface quality, high foreshortening, and good radiopacity. The EGIS single bare demonstrated high RF, high CR, low AF, moderate conformability, good surface quality, high foreshortening, and poor radiopacity. The Zilver 635® displayed moderate RF, low CR, low AF, moderate conformability, moderate surface quality, no foreshortening, and good radiopacity. The E-Luminexx™ showed high RF, moderate CR, high AF, poor conformability, poor surface quality, no foreshortening, and good radiopacity. CONCLUSIONS: There was considerable variation in the characteristics among the four evaluated SEMSs. These characteristics should be carefully considered during selection to ensure optimal therapeutic outcomes for patients. RELEVANCE STATEMENT: The selection of self-expanding metal stents for treating malignant biliary obstruction requires careful consideration of various characteristics, including their radial force, crush resistance, axial force, conformability, surface quality, foreshortening, and radiopacity. KEY POINTS: • The characteristics of self-expanding metal stents (SEMSs) can vary considerably. • Specific situations may warrant the use of SEMSs with particular characteristics over others. • Characteristics of SEMSs must be considered during selection for optimal outcomes.


Assuntos
Colestase , Stents , Humanos
6.
Clin Endosc ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38389304

RESUMO

Malignant gastric outlet obstruction (GOO) is a condition characterized by blockage or narrowing where the stomach empties its contents into the small intestine due to primary malignant tumors or metastatic diseases. This condition leads to various symptoms such as nausea, vomiting, abdominal pain, and weight loss. To manage malignant GOO, different treatment options have been employed, including surgical gastrojejunostomy (SGJ), gastroduodenal stenting (GDS) using self-expandable metallic stent (SEMS), and endoscopic ultrasound-guided gastrojejunostomy (EUS-GJ). This review focuses on comparing the clinical outcomes of endoscopic stenting (GDS and EUS-GJ) with SGJ for malignant GOO. Studies have shown that GDS with SEMS provides comparable clinical outcomes and safety for the palliation of obstructive symptoms. The choice between covered and uncovered SEMS remains controversial, as different studies have reported varying results. EUS-GJ, performed via endoscopic ultrasound guidance, has shown promising efficacy and safety in managing malignant GOO, but further studies are needed to establish it as the primary treatment option. Comparative analyses suggest that GDS has higher recurrence and reintervention rates compared to EUS-GJ and SGJ, with similar overall procedural complications. However, bleeding rates were lower with GDS than with SGJ. Randomized controlled trials are required to determine the optimal treatment approach for malignant GOO.

8.
World J Clin Cases ; 11(34): 8235-8241, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38130794

RESUMO

BACKGROUND: One challenging scenario in the treatment of biliary stricture is that post-liver transplantation (LT) biliary strictures cannot be accessed using endoscopic retrograde cholangiopancreatography (ERCP). Here, we report such a case that was successfully treated using a novel endoscopic technique. CASE SUMMARY: A 60-year-old man presented with obstructive jaundice caused by a post-LT biliary stricture. He underwent LT for compensated alcoholic liver cirrhosis and hepatocellular carcinoma. Laboratory investigations unveiled a cholestatic pattern of abnormalities in liver function and a total bilirubin level of 16 mg/dL. Magnetic resonance cholangiopancreatography revealed a stricture extending from the right intrahepatic bile duct into the common hepatic duct. Severe postoperative deformities made accessing the ampulla of Vater with a side-viewing duodenoscope impossible. Percutaneous transhepatic biliary drainage (PTBD) was performed to treat biliary obstruction. Moreover, to resolve the stricture completely, a fully covered self-expandable metal stent (FC-SEMS) with a novel proximal retrievable string was deployed into the post-LT biliary stricture through the PTBD tract. Before inserting the stent through the PTBD tract, the stent with the distal string was manually inverted to ensure that the distal part with the string became the proximal part for later endoscopic removal. After 6 mo, the FC-SEMS was successfully removed without complications, as the string was pulled out using a forward-viewing gastroscope. CONCLUSION: Deployment and endoscopic removal of an FC-SEMS with a novel proximal string through the PTBD tract may be a viable option for treating post-LT biliary strictures that are inaccessible by ERCP.

9.
J Vasc Surg Cases Innov Tech ; 9(3): 101287, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37799840

RESUMO

Hepatic caval stenosis is managed with stenting; however, stent placement can be complicated by migration, which can be life-threatening. The risk of migration can be mitigated by increasing the length of the stent, which increases contact with the vessel wall. We describe the cases of three patients with hepatic caval stenosis treated with two Z-stents sutured together. Each had an uncomplicated postoperative course and demonstrated clinical improvement. The use of sutured Z-stents can increase the stability of the stent and, therefore, decrease the morbidity associated with stent placement for hepatic caval stenosis.

10.
J Vasc Surg Cases Innov Tech ; 9(3): 101143, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37799850

RESUMO

Femoropopliteal disease comprises more than one half of lesions in peripheral vascular disease. The treatment modalities for stenosis or occlusion of this anatomic region include femoropopliteal bypass and percutaneous transluminal angioplasty with or without stenting. Our patient developed acute leg ischemia 3 years after stenting, secondary to stent fracture, with distal embolization of stent fragments. Using mechanical thromboembolectomy and superficial femoral artery to below-the-knee popliteal in situ saphenous vein bypass, we were able to restore perfusion to the limb and retrieve fragments of the fractured stent.

11.
J Clin Med ; 12(13)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37445390

RESUMO

This study evaluated the prevalence and risk factors of early- (within 7 days of placement) and late-onset (after 7 days of placement) cholecystitis after Y-configured metal stent placement. Between June 2005 and August 2020, 109 patients who had been treated with Y-configured metal stents for malignant hilar obstruction were enrolled in the study. We retrospectively analyzed the potential risk factors for post-stent cholecystitis. The presence of diabetes (p = 0.042), the length of the common part of the Y-stent (p = 0.017), filling of the gallbladder with contrast medium during the procedure (p = 0.040), and tumor invasion of the cystic duct accompanied by filling the gallbladder with contrast medium during metal stent placement (p = 0.001) were identified as important risk factors. In cases of late-onset cholecystitis, stent obstruction (p = 0.004) and repeated endoscopic procedures due to stent malfunction (p = 0.024) were significant risk factors. In the multivariate logistic regression analysis, significant risk factors were the length of the common part of the Y-stent (p = 0.032) in early-onset cholecystitis and stent obstruction (p = 0.007) in late-onset cholecystitis. This study demonstrated that early-onset cholecystitis may occur in patients according to the length of the common portion of the Y-stent. In contrast, late-onset cholecystitis may occur in patients with stent obstruction.

12.
Clin Endosc ; 56(6): 761-768, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37491991

RESUMO

BACKGROUND/AIMS: Self-expandable metallic stents (SEMSs) are widely adopted for the palliation of dysphagia in patients with malignant esophageal strictures. An important adverse event is the development of SEMS-induced esophagorespiratory fistulas (SEMS-ERFs). This study aimed to assess the risk factors related to the development of SEMS-ERF after SEMS placement in patients with esophageal cancer. METHODS: This retrospective study was performed at the Instituto do Cancer do Estado de São Paulo. All patients with malignant esophageal strictures who underwent esophageal SEMS placement between 2009 and 2019 were included in the study. RESULTS: Of the 335 patients, 37 (11.0%) developed SEMS-ERF, with a median time of 129 days after SEMS placement. Stent flare of 28 mm (hazard ratio [HR], 2.05; 95% confidence interval [CI], 1.15-5.51; p=0.02) and post-stent chemotherapy (HR, 2.0; 95% CI, 1.01-4.00; p=0.05) were associated with an increased risk of developing SEMS-ERF, while lower-third tumors were a protective factor (HR, 0.5; 95% CI, 0.26-0.85; p=0.01). No difference was observed in overall survival. CONCLUSION: The incidence of SEMS-ERFs was 11%, with a median time of 129 days after SEMS placement. Post-stent chemotherapy and a 28 mm stent flare were associated with a higher risk of SEMS-ERF.

13.
Ann Gastroenterol Surg ; 7(4): 583-593, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37416739

RESUMO

Aim: To compare the oncological outcomes between self-expandable metallic stent (SEMS) as a bridge to surgery and transanal decompression tube (TDT) placement for malignant large bowel obstruction (MLBO). Methods: A total of 287 MLBO patients who underwent SEMS (n = 137) or TDT placement (n = 150) were enrolled in this multicenter retrospective study. Overall survival (OS) and disease-free survival (DFS) between the two groups were compared. A meta-analysis was performed using random-effects models to calculate odd ratios (OR) with 95% confidence intervals (CIs). Results: Postoperative complications of Clavien-Dindo grade ≥II and ≥III occurred frequently in the TDT group compared with the SEMS group (P = 0.002 and 0.005, respectively). The 3-y OS in the overall cohort and 3-y DFS in the pathological stage II/III cohort in the SEMS and TDT groups were 68.6% and 71.4%, and 71.0% and 72.6%, respectively. The survival differences were not significantly different in the OS and DFS analyses (P = 0.819 and P = 0.892, respectively). A meta-analysis of nine studies (including our cohort data) demonstrated no significant difference between the SEMS and TDT groups for 3-y OS and DFS (OR = 0.96, 95% CI = 0.57-1.62, P = 0.89 and OR = 0.69, 95% CI = 0.46-1.04, P = 0.07, respectively). Conclusion: Our study demonstrated that SEMS placement had no inferiority regarding long-term outcomes, including OS and DFS, compared with TDT placement. Considering the short-term benefits of SEMS placement, this could be a preferable preoperative decompression method for MLBO.

14.
Dig Dis Sci ; 68(9): 3756-3764, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37439926

RESUMO

BACKGROUND AND AIMS: In patients with unresectable malignant biliary obstruction (MBO), endoscopic biliary drainage is the treatment of choice. Self-expanding metallic stents (SEMS) are mainly used for this purpose, and data is limited on the comparative outcomes of laser-cut versus braided SEMS. Herein, we performed the first systematic review and meta-analysis to study the effectiveness and safety of braided and laser-cut SEMS in MBO. METHODS: Multiple databases, including Medline, Scopus, and Embase, were searched (in May 2022) using specific terms for studies evaluating the outcomes of braided and laser-cut SEMS in MBO. Outcomes of interest were technical and clinical success, recurrent biliary obstruction, and adverse events. Standard meta-analysis methods were employed using the random-effects model. I2% heterogeneity was used to assess the heterogeneity. RESULTS: Seven studies were included in the final analysis. (Laser-cut: 271 patients, 46% females, mean age 70 years; and braided: 282 patients, 47% females, mean age 72 years). The pooled rate of technical success and clinical success with laser-cut SEMS was 99% (95% CI [95-99; I2 = 0%]), 86% [60-96; I2 = 74%], and 98% [96-99; I2 = 0%], 89% [74-95; I2 = 78%] with braided. The pooled rate of recurrent biliary obstruction with laser-cut SEMS was 26% [14-43; I2 = 88%] and 12% [5-27; I2 = 56%) with braided. Pooled total adverse events were 11% [5-21; I2 = 77%] in laser-cut and 12% [6-24; I2 = 63%] in braided. CONCLUSION: Our meta-analysis demonstrates similar clinical outcomes with laser-cut and braided SEMS in MBO. Given the comparable performance, a cost-effectiveness analysis might help in choosing one type versus another in patients with MBO.


Assuntos
Colestase , Stents Metálicos Autoexpansíveis , Feminino , Humanos , Idoso , Masculino , Stents , Colestase/etiologia , Colestase/cirurgia , Constrição Patológica/etiologia , Stents Metálicos Autoexpansíveis/efeitos adversos , Estudos Retrospectivos
15.
ACS Appl Mater Interfaces ; 15(29): 34475-34487, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37452740

RESUMO

The application of irreversible electroporation (IRE) to endoluminal organs is being investigated; however, the current preclinical evidence and optimized electrodes are insufficient for clinical translation. Here, a novel self-expandable electrode (SE) made of chemically polished nickel-titanium (Ni-Ti) alloy wire for endoluminal IRE is developed in this study. Chemically polished heat-treated Ni-Ti alloy wires demonstrate increased electrical conductivity, reduced carbon and oxygen levels, and good mechanical and self-expanding properties. Bipolar IRE using chemically polished Ni-Ti wires successfully induces cancer cell death. IRE-treated potato tissue shows irreversibly and reversibly electroporated areas containing dead cells in an electrical strength-dependent manner. In vivo study using an optimized electric field strength demonstrates that endobiliary IRE using the SE evenly induces well-distributed mucosal injuries in the common bile duct (CBD) with the overexpression of the TUNEL, HSP70, and inflammatory cells without ductal perforation or stricture formation. This study demonstrates the basic concept of the endobiliary IRE procedure, which is technically feasible and safe in a porcine CBD as a novel therapeutic strategy for malignant biliary obstruction. The SE is a promising electrical energy delivery platform for effectively treating endoluminal organs.


Assuntos
Neoplasias , Titânio , Suínos , Animais , Titânio/química , Níquel/química , Eletroporação/métodos , Eletrodos , Ligas
16.
World J Clin Oncol ; 14(5): 190-197, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37275939

RESUMO

The therapy of left-sided malignant colonic obstruction continues to be one of the largest problems in clinical practice. Numerous studies on colonic stenting for neoplastic colonic obstruction have been reported in the last decades. Thereby the role of self-expandable metal stents (SEMS) in the treatment of malignant colonic obstruction has become better defined. However, numerous prospective and retrospective investigations have highlighted serious concerns about a possible worse outcome after endoscopic colorectal stenting as a bridge to surgery, particularly in case of perforation. This review analyzes the most recent evidence in order to highlight pros and cons of SEMS placement in left-sided malignant colonic obstruction.

17.
Clin J Gastroenterol ; 16(5): 743-747, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37306865

RESUMO

We report the case of a 65-year-old man who experienced hemobilia due to rupture of a pseudoaneurysm of the left hepatic artery after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS). The patient was diagnosed with pancreatic cancer and underwent endoscopic retrograde cholangiopancreatography for obstructive jaundice. Biliary drainage was converted to EUS-HGS due to tumor invasion in the superior duodenal angle. A partially covered metal stent was placed in the B3 intrahepatic bile duct. The procedure was completed without early complications, but 50 days later, the patient developed fever, elevated hepatobiliary enzymes, and shock. Contrast-enhanced computed tomography (CT) showed that the hepatic end of the HGS stent had moved slightly toward the stomach compared to the previous CT. A 6-mm pseudoaneurysm was also observed near the A3 and A4 branches of the left hepatic artery, coinciding with the hepatic end of the EUS-HGS stent. Hemostasis was achieved with coil embolization. Biliary hemorrhage due to rupture of a pseudoaneurysm should be considered in the differential diagnosis of biliary obstruction accompanied by bleeding after EUS-HGS.


Assuntos
Falso Aneurisma , Neoplasias dos Ductos Biliares , Colestase , Hemobilia , Idoso , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Neoplasias dos Ductos Biliares/complicações , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colestase/etiologia , Drenagem/métodos , Endossonografia/métodos , Hemobilia/terapia , Hemobilia/complicações , Fígado/patologia , Ultrassonografia de Intervenção/efeitos adversos , Stents/efeitos adversos
18.
J Korean Soc Radiol ; 84(3): 615-626, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37324992

RESUMO

Purpose: To assess the outcomes of single-stage surgery following fluoroscopic stent placement for malignant colorectal obstruction. Materials and Methods: This retrospective study included 46 patients (28 male and 18 female; mean age, 67.2 years) who had undergone fluoroscopic stent placement followed by laparoscopic resection (n = 31) or open surgery (n = 15) for malignant colorectal obstruction. The surgical outcomes were analyzed and compared. After a mean follow-up of 38.9 months, the recurrence-free and overall survival were estimated, and prognostic factors were evaluated. Results: The mean interval between stent placement and surgery was 10.2 days. Primary anastomosis was possible in all patients. The mean postoperative length of hospitalization was 11.0 days. Bowel perforation was detected in six patients (13.0%). During the follow-up, ten patients (21.7%) developed recurrence; these included five of the six patients with bowel perforation. Bowel perforation had a significant effect on recurrence-free survival (p = 0.010). Conclusion: Single-stage surgery following fluoroscopic stent placement may be effective for treating malignant colorectal obstruction. Stent-related bowel perforation is a significant predictive factor for tumor recurrence.

19.
Gut Liver ; 17(5): 806-813, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37013456

RESUMO

Background/Aims: The use of a self-expandable metal stent (SEMS) is recommended for unresectable malignant biliary obstruction (MBO). Stent-related adverse events might differ according to the position of the stent through the ampulla of Vater (AOV). We retrospectively evaluated SEMS patency and adverse events according to the position of the SEMS. Methods: In total, 280 patients who underwent endoscopic SEMS placement due to malignant distal biliary obstruction were analyzed retrospectively. Suprapapillary and transpapillary SEMS insertions were performed on 51 patients and 229 patients, respectively. Results: Between the suprapapillary group (SPG) and transpapillary group (TPG), the stent patency period was not significantly different (median [95% confidence interval]: 107 days [82.3 to 131.7] vs 120 days [99.3 to 140.7], p=0.559). There was also no significant difference in the rate of adverse events. In subgroup analysis, the stent patency for an MBO located within 2 cm from the AOV was found to be significantly shorter than that for an MBO located more than 2 cm from the AOV in the SPG (64 days [0 to 160.4] vs 127 days [82.0 to 171.9], p<0.001) and TPG (87 days [52.5 to 121.5] vs 130 [97.0 to 162.9], p<0.001). Patients with an MBO located within 2 cm from the AOV in both groups had a higher percentage of duodenal invasion (SPG: 40.0% vs 4.9%, p=0.002; TPG: 28.6% vs 2.9%, p<0.001) than patients with an MBO located more than 2 cm from the AOV. Conclusions: The SPG and TPG showed similar results in terms of stent patency and rate of adverse events. However, patients with an MBO located within 2 cm from the AOV had a higher percentage of duodenal invasion with shorter stent patency than those with an MBO located more than 2 cm from the AOV, regardless of stent position.


Assuntos
Ampola Hepatopancreática , Colestase , Neoplasias , Stents Metálicos Autoexpansíveis , Humanos , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Neoplasias/etiologia , Stents/efeitos adversos , Ampola Hepatopancreática/cirurgia , Colestase/etiologia , Colestase/cirurgia
20.
Rev. argent. cardiol ; 91(1): 20-26, abr. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1529566

RESUMO

RESUMEN Objetivo : Analizar si la estrategia del implante alto usando superposición de las cúspides derechas e izquierdas (Cusp Overlap, COVL) en el implante percutáneo de la válvula aórtica (TAVI) se relaciona con menor incidencia de regurgitación paravalvular (RPV) moderada o grave, comparada con la estrategia convencional (CON). Material y métodos : Se analizaron 206 pacientes consecutivos que recibieron TAVI con válvulas autoexpandidles entre agosto de 2019 y mayo de 2022. Se utilizó una estrategia CON en 101 pacientes (49%) y COVL en 105 (51%). El Punto Final Primario (PFP) fue la presencia de regurgitación paravalvular moderada y grave a 30 días. Resultados : No hubo diferencia clínica entre los grupos en cuanto a la edad media, sexo ni comorbilidades; excepto una tendencia a más diabetes y angioplastia coronaria previa en el grupo COVL. El STS score fue mayor en el grupo de COVL (6,9 ± 2,2 vs. 5,8 ± 2,4 en CON, p = 0,01). A 30 días no hubo diferencia en el PFP (RPV moderada en 2% en CON, y 0,9% en COVL; ninguno presentó RPV grave). Tampoco hubo diferencia en mortalidad, infarto, oclusión coronaria, accidente cerebrovascular, sangrado mayor y complicación vascular. La necesidad de marcapasos definitivo fue menor con la estrategia de COVL (6,7% vs. 17,8%, p = 0,01) y un nuevo bloqueo de rama izquierda ocurrió en 5,7% vs. 12,9% (p = 0,07). Conclusiones : En esta serie de un solo centro, la estrategia del implante alto de la válvula aórtica percutánea usando la técnica de COVL no demostró diferencia en la presencia de regurgitaciones moderadas o graves comparada con la estrategia convencional, sin presentar diferencia en las complicaciones, y se asoció a una menor necesidad de marcapasos definitivo y a una tendencia de menos bloqueos de rama izquierda a 30 días.


ABSTRACT Objective : The aim of this study is to whether higher transcatheter aortic valve implantation (TAVI) with self-expandable valves using the right and left cusp overlap strategy (Cusp Overlap, COVL) is associated with a lower incidence of moderate or severe paravalvular regurgitation, compared with the conventional strategy (CON). Methods : A total of 206 consecutive patients undergoing TAVI with self-expandable valves between August 2019 and May 2022 were analyzed. The CON technique was used in the first 101 patients (49%) and COVL was used in 105 (51%). The primary endpoint (PEP) was the presence of moderate or severe paravalvular regurgitation at 30 days. Results : There were no clinical differences between the groups in terms of mean age, sex or comorbidities, except for a trend towards more patients with diabetes and previous percutaneous coronary intervention in the COVL group. The STS score was greater in the COVL group (6.9 ± 2.2 vs. 5.8 ± 2.4 in the CON group; p = 0.01). There was no difference in the PEP at 30 days with 2% incidence of moderate PVR in the CON group and 0.9% in the COVL group, and none of them presented severe PVR. There were no differences in mortality, myocardial infarction, coronary artery obstruction, stroke, major bleeding or vascular complications. The need for permanent pacemaker was lower with the COVL strategy (6.7% vs. 17.8%, p = 0.01) and a new left bundle branch block occurred in 5.7% vs. 12.9% (p = 0.07). Conclusions : In this single-center series, the strategy of high transcatheter aortic valve implantation using the COVL strategy showed no difference in the presence of moderate or severe regurgitation compared with the conventional strategy, with no differences in complications, and was associated with a lower need for definitive pacemaker and with a trend towards lower incidence of left bundle branch block at 30 days.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...